Digital SINE Controller Specifications
DISPLAY MONITOR:
- SWEEP: Frequency, direction, rate (Log or Lin), lower limit, upper limit, sweep count.
- COMPRESSOR: Rate, speed, dB of compression.
- ACCELERATION: 0 to 200 g-pk.
- VELOCITY: 0 to 200 in /sec
- DISPLACEMENT: 0 to 10 in. pk-pk.
- TIME: Time, date, test run time.
- UNITS: English or Metric.
Download PDF: DVC -4/8 Digital Swept-Sine Controller Operating Manual
TEST ARTICLE PROTECTION:
- ABORT LIMIT: Settable 1 to 99 dB abort, Settable system limits for D,V, and A. Low-level gain and open-loop checks.
- OVERALL LIMITS: Overall D,V,A limits settable by user.
- CONTROL SIGNAL LOSS: Open loop detector.
- MANUAL ABORT: From keyboard or mouse.
TEST DOCUMENTATION:
Any of the following plots can be stored on disk or printed out in color or black and white on any Windows compatible printer.
- CONTROL CHANNEL: Control profile.
- MONITOR CHANNEL: Response profile.
- CONTROL/MONITOR: Control profile and response profile.
SYSTEM REQUIREMENTS:
- COMPUTER: 486DX33 or better with vga display, 8 mb ram, hard disk and Windows 3.1 minimum, Pentium with 16mb ram and Windows 95 recommended.
- POWER REQUIREMENTS: Powered by computer buss, <10W total.
- SIZE: Standard AT 3/4 size PC card (9.5° x 4.625°).
- SEXTERNAL CONNECTIONS: Via DB-25 connector to junction box.
FREQUENCY:
- RANGE: 2 to 6250 Hz, digitally synthesized.
- STABILITY: +/- 100ppm/°C, crystal-controlled.
- DISTORTION: <0.50% thd 0.25% typical.
- LIMITS: Sweeps between programmed upper and lower limits.
SWEEP MODES:
- CONTINUOUS: Up to 9999 cycles between set limits.
- HALF-CYCLE: Up or down for response plotting.
- MANUAL: With keyboard arrows.
- SWEEP: Logarithmic, linear, or Mil 167.
SWEEP RATES:
- 0.1 to 9.99 oct/min for log or 0.1 to 99.9 Hz/sec for linear.
SIGNAL INPUTS:
- INPUT CHANNELS: Two channels: one control & one monitor
- INPUT SENSITIVITY: Settable from 8 to 1000 mvg, 20 vp-pmax input.
- CURRENT SOURCES: 4 ma each input, 18 vdc compliance on each channel.
SIGNAL OUTPUT:
- SERVO OUT: 0-5 vrms for amplifier drive, short protected.
TEST PROFILES:
- Up to 32 frequency breakpoints or levels of D,V. or A may be specified for each test; profiles may be stored on disks.
SERVO COMPRESSOR:
- DYNAMIC RANGE: >70 dB.
- CONTROL ACCURACY: <+/- 0.5 dB nominally.
- COMPRESSION RATE: Slow- 0.1 dB/sec/Hz, Med – 0 3 dB/sec/Hz, Fast- 1.0 dB/sec/HZ.
- COMPRESSION SPEED LIMIT: Programmable from 200 to 1000 dB/sec.
- CONTROL LIMITS: From 0.2 to 200 g with 10 mv/g input.